Published August 18, 2023 | Version v1
Report Open

Gas Flux System

  • 1. ROR icon American University of the Middle East

Contributors

  • 1. ROR icon Rio de Janeiro State University

Description

This report will go through the importance of adding a gas flux system in the CMS "RPC" LAB's as well as the process of creating said system. For this design we will use the esp32 microcontroller in conjunction with the D6F-P0010A2 flow sensor. This system will mainly be used in order to monitor and control the gas flow within the RPC chambers in the laboratory. We will discuss the importance of reducing these gas emissions, the purpose of doing so and some of the effects that these emissions might have on the environment. Lastly this report will discuss some results and data collected using said system.

Files

CMS (Gas Flux System).pdf

Files (1.8 MB)

Name Size Download all
md5:c2deb8bec75cb2d13fac353b139c94ee
1.8 MB Preview Download

Additional details

Identifiers

CDS Reference
CERN-STUDENTS-Note-2023-047

CERN

Department
EN
Experiment
CMS