Published August 1, 2016 | Version v1

Program to make remote time measurement on the new precise clock system on totem

Authors/Creators

Contributors

Description

For my project at CERN, I worked in the TOTEM team with Michele Quinto and Francesco Cafagna as supervisors. Their team is currently working on an update on TOTEM that includes a module able to measure precisely the time of flight of particles emitted from the collision at CMS. With this additional data, TOTEM will be able to reconstruct precisely the point of the collision in CMS. The main problem posed for this new module is to provide a precise synchronized clock signal to both the TOTEM detectors situated 200 meters after and before CMS. In fact, due to some external parameters, as temperature, the length of the optical fiber guiding the clock signal can vary yielding thus a unwanted phase difference of the clock between the two detectors. The idea is to get rid of the noisy phase difference to make very precise time of flight measurement of the order of the picosecond. This is achieved by continuously measuring the phase difference and correcting the time measurements according to the current phase difference.

Files

report_cern.pdf

Files (454.4 kB)

Name Size Download all
md5:3c91e6998cbba6a2b21f9828c8f50f87
454.4 kB Preview Download

Additional details

Identifiers

CDS Report Number
CERN-STUDENTS-Note-2016-010

Linked records