Active radiation monitors are distributed in and around the LHCb experiment in order to monitor the evolution of radiation dose and 1 MeV equivalent neutron fluence. The active monitors are connected to an online network and their raw voltage measurement can be read out via WinCC panels. However, the raw voltage measurements must be corrected before conversion into correct dose or fluence. Previous work by [1] included a signal correction algorithm that corrects the values offline. The aim of this work is to understand how the signal correction algorithm works, archive previously corrected values into a new database system that will be integrated to a WinCC graphical interface and modify the algorithm so that it may process new values online while using less time and computing resources.