Published August 21, 2015 | Version v1

Total Ionizing Dose Testing of the ABC130 ASIC for the ATLAS Phase-II Semiconductor Tracker Upgrade

Authors/Creators

  • 1. ROR icon Institute of Plant Protection

Contributors

Supervisor:

Description

The Large Hadron Collider's (LHC) current inner detector was not built to withstand the radiation damage from the 3000 $\text{fb}^{-1}$ of integrated luminosity that is planned for the high luminosity LHC (HL-LHC). Therefore, the ATLAS inner detector (ID) must be completely upgraded. As a part of this upgrade, the semiconductor tracker (SCT) and transition radiation tracker (TRT) will be replaced with new silicon microstrip sensors {[}1{]}. These silicon strips will be read out by the ABC130 chip and thus the ABC130 must be able to withstand an expected 30 Mrad of radiation over 10 years. The ABC130 chip was irradiated with 70 Mrad of x-ray radiation over the course of 2 days and the results are discussed in this report.

Files

IppReportB2015_AlanMorningstar.pdf

Files (2.7 MB)

Name Size Download all
md5:4b0a161d2549258c296caa2323a31d68
2.7 MB Preview Download

Additional details

Identifiers

CDS Report Number
CERN-STUDENTS-Note-2015-122

CERN

Department
PH - Physics Department
Experiment
ATLAS

Linked records