Published September 3, 2021
| Version v1
Technical note
Open
Performance study for different geometries of the future Noble Liquid calorimeter at FCC-ee
Contributors
Supervisor (2):
Description
This document summarizes detector performance studies carried out for different versions of the Noble Liquid electromagnetic calorimeter proposed for FCC-ee. The energy and angular resolutions are presented for various combinations of absorber material, Noble Liquid and sensitive gap thickness. In addition to this, the effect of the cell merging strategy at the read-out level is also evaluated.
Files
FCCeeNobleLiquidCalorimetryStudies.pdf
Files
(1.2 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:e2e0806941e3dfa4839eeae5d3ca36c2
|
1.2 MB | Preview Download |
Additional details
Identifiers
- CDS Report Number
- CERN-STUDENTS-Note-2021-116
CERN
- Department
- EP - Experimental Physics Department
- Experiment
- FCC
- Projects
- CERN-EP-RDET