Published December 23, 2024
| Version v2
Technical note
Restricted
Electromagnetic calorimetry requirements from flavour physics for application at FCC-ee
Authors/Creators
- 1. Université Clermont-Auvergne, CNRS, LPCA, 63000 Clermont-Ferrand, France
- 2. Department of Physics, TU Dortmund University, Dortmund, Germany
Description
This technical note reports an academic exercise to assess the electromagnetic (EM) calorimeter energy resolution performance that would be needed in order to separate candidates of the radiative quark transitions $b \to s \gamma$ and $b\to d \gamma$. The specific measurement considered in this work, the relative branching fractions of the decays $\overline{B}^0 \to K^{*0}(892)\gamma$ and $B^0_s \to K^{*0}(892) \gamma$ can only be performed with a stochastic term of the EM well-below 10%.
Files
Additional details
Funding
- European Commission
- FCCIS - Future Circular Collider Innovation Study 951754