Collision-energy calibration and monochromatisation studies at FCC-ee
Authors/Creators
Description
The Future Circular Collider (FCC) technical and financial Feasibility Study (FS) includes a work package on Energy Calibration, Polarisation and Monochromatisation (EPOL), which is concerned with the precision determination of the centre-of-mass energy at the e+e− machine, FCC-ee. To achieve this goal it is proposed to use resonant depolarisation and possibly spin precession measurements, in conjunction with precise measurement by the detectors of the energy spread and other parameters with physics events. Beam diagnostics, provided by polarimeters and beam-position monitors, play an essential role in monitoring the polarisation level and controlling numerous beam parameters at the interaction point. Specific items of accelerator equipment include polarisation wigglers and depolarising RF-kickers. The target is to achieve a precision commensurate to the remarkable statistical precision achievable in the physics experiments. The possible monochromatisation of colliding beams in view of a measurement of the e+e−→H(125) process is also being studied, with the specific requirements of this procedure under investigation. A review is presented of the status of these activities at the end of the FS, together with the outlook for future work.
Files
EPOL_support_note_final_report_20250423.pdf
Files
(10.8 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:56ac10e9d8038e2cd879fe4797492c70
|
10.8 MB | Preview Download |
Additional details
Related works
- Is referenced by
- Text: 2925290 (Inspire)
- Is variant form of
- Other: 10.17181/mbyss-ncb42 (DOI)
Funding
- European Commission
- FCCIS - Future Circular Collider Innovation Study 951754