Description

In the ATLAS detector, the resistive plate chambers (RPCs) provide the first-level muon trigger and the measurement of the coordinate in the muon spectrometer. RPCs which have high time resolution, are installed parallel to the muon drift tubes (MDTs), which have high spacial resolution. This summer project revolves around plotting the efficiency curve of the newly developed RPC-like cylindrical detector, which is called resistive cylindrical chambers (RCCs).

Files

CERN_summer_student_report.pdf

Files (1.0 MB)

Name Size Download all
md5:6c59db0155dc631060a0947a8459fed0
1.0 MB Preview Download

Additional details

CERN

Experiment
ATLAS

References

  • R. Cardarelli, A. Rocchi, G. Aielli, P. Camarri, A. Di Ciaccio, L. Di Stante, B. Liberti, E. Pastori, and G. Proto, Nu- clear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 1058, 168822 (2024).
  • Anonymous, "Resistive cylindrical chambers," (n.d.), https://cms.cern/detector/detecting-muons/ resistive-plate-chambers.
  • A. Collaboration et al., arXiv preprint arXiv:2103.01029 (2021).