Published October 1, 2020 | Version v1
Technical note Restricted

The effects of pump-down to straw stations in the SHiP decay volume

Authors/Creators

Contributors

Supervisor:

Description

This note investigates the hypothetical negative effects of a pump-down process to tracker stations within the SHiP spectrometer vessel due to restricted airflow and pressure differences. By considering a proposed tracker station design that reflects the 'worst case' scenario, both an analytical and a CFD model (using ANSYS Fluent) are presented. Simplified assumptions within the analytical model favour the computational model's results. This model predicts that for a given 10 cm gap, the forces upon the tracker station would be < 100 N and have pressure differences < 1 Pa.

Files

Restricted

The record is publicly accessible, but files are restricted. Log in to check if you have access.

Additional details

Identifiers

CDS Report Number
CERN-STUDENTS-Note-2020-019

Linked records