Published November 10, 2017 | Version v1

Study of signal discrimination for timing measurements

Authors/Creators

Description

The timing detectors of the CMS-TOTEM Precision Proton Spectrometer (CT-PPS) are currently read out using discrete components, separated into three boards; the first board hosts the sensors and the amplifiers, the second one hosts the discriminators and the third is dedicated to the Time to Digital Converter (TDC) and to the interface with the data acquisition system (DAQ). This work proposes a new front-end electronics for the timing detector, with sensors, amplifiers and discriminators integrated on the same board. We simulated an updated version of the amplifier together with a discriminator designed using commercial components. We decided to use an LVDS buffer as a discriminator, because of its cost, availability, speed and lo w power consumption. As a proof of concept, we used the LVDS input of an FPGA to discriminate signals produced by a detector prototype, using a radioactive source.

Files

summer-student-report.pdf

Files (1.0 MB)

Name Size Download all
md5:73e0fc5ffd4bd080d2e3e6b61fe933e1
1.0 MB Preview Download

Additional details

Identifiers

CDS Report Number
CERN-STUDENTS-Note-2017-240

Linked records