Published August 13, 2015 | Version v1

RPC Performance study using 2012 and 2015 data

Authors/Creators

  • 1. ROR icon Compact Membrane Systems (United States)

Description

Resistive Plate Chambers are the dedicated trigger muon detector for the Compact Muon Solenoid experiment at the Large Hadron Collider at CERN. HV50 is one of the parameter under study to eventually spot any aging effect. The comparative study is done for Barrel and Endcap region particularly, and as a whole too confirming the excellent behavior of RPC detector and fulfillment of requirement as per decided before the upgrade.

Files

Files (126.7 kB)

Name Size Download all
md5:bf4e65859bb3b6ab4cbedf68d17a1b2c
126.7 kB Download

Additional details

Identifiers

CDS Report Number
CERN-STUDENTS-Note-2015-053

CERN

Department
PH - Physics Department
Experiment
CMS

Linked records