Published May 15, 2008
| Version v1
Thesis
Open
Design and Construction of a Beam Position Monitor Prototype for the Test Beam Line of the CTF3
Description
A prototype of Beam Position Monitor (BPM) for the Test Beam Line (TBL) of the 3rd CLIC Test Facility (CTF3) at CERN has been designed and constructed at IFIC in collaboration with the CERN CTF3 team. The design is a scaled version of the BPMs of the CTF3 linac. The design goals are a resolution of 5 μm, an overall precision of 50 μm, in a circular vacuum chamber of 24 mm, in a frequency bandwidth between 10 kHz and 100MHz.The BPMis an inductive type BPM. Beam positions are derived from the image current created by a high frequency electron bunch beam into four electrodes surrounding the vacuum chamber. In this work we describe the mechanical design and construction, the description of the associated electronics together with the first calibration measurements performed in a wire test bench at CERN.
Files
CERN-OPEN-2009-002.pdf
Files
(10.4 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:f09ee6eceede9632fbb0ceb340b17ddf
|
5.3 MB | Preview Download |
|
md5:a7813687c08a3493a98d45065f57e40a
|
5.2 MB | Preview Download |
Additional details
Identifiers
- CDS
- 1164156
- CDS Report Number
- CERN-THESIS-2009-009
- Aleph number
- 000701953CER
- CDS Report Number
- CLIC-Note-769
- CDS Report Number
- CERN-OPEN-2009-002
Related works
- Is variant form of
- Other: 809122 (Inspire)
CERN
- Programme
- No program participation
- Accelerator
- CLIC
- Experiment